Drain, Hemoglobin, PSI, TKA, TXAAbstract
Background: This study investigates how presence or absence of drain or tranexamic acid (TXA) in 2 different types of instrumentation with invasion/sparing femoral canal affects hemoglobin drop after total knee arthroplasty (TKA).
Methods: This was a retrospective observational study that included 736 individuals divided in five groups, regarding conventional instrumentation (CI) or patient specific instrumentation (PSI), presence or absence of drain and TXA. Mean percentage of hemoglobin drop after the first postoperative day was compared for each group.
Results: Patients submitted to CI using drain and no TXA revealed the highest value (21,3%±9,1; p<0,001). Groups who received TXA and drain was not used, presented the lowest blood loss. Moreover, with the introduction of TXA PSI lost its advantage over CI.
Conclusions: TKA using CI, without drain and with TXA administration showed better results, reducing mean percentage of hemoglobin drop after surgery.
References
Liao L, Chen Y, Tang Q, Yi-Yue C, Wan-Chun W. Tranexamic acid plus drain clamping can reduce blood loss in total knee arthroplasty: A systematic review and meta-analysis. Int J Surg. 2018;52:334.
Boutsiadis A, Reynolds RJ, Saffarini M, Panisset P. Factors that influence blood loss and need for transfusion following total knee arthroplasty. Ann Transl Med. 2017;5(21):418.
Themistoklis T, Theodosia V, Konstantinos K, Georgios D. Perioperative blood management strategies for patients undergoing total knee replacement: Where do we stand now? World J Orthop. 2017;8(6):441-54.
Jeon S, Park JS, Kim MK. Optimal release timing of temporary drain clamping after total knee arthroplasty. J Orthop Surg Res. 2017;12:47.
Wu Y, Yang T, Zeng Y, Canfeng L, Bin S, Fuxing P. Clamping drainage is unnecessary after minimally invasive total knee arthroplasty in patients with tranexamic acid-A randomized, controlled trial. Medicine. 2017;96:7:e5804.
Basilico M, Vitiello R, Liuzza F, Felice M, Pasquale R, Maria RM, et al. Efficacy of postoperative drainage in total knee arthroplasty: Review of the literature. Orthop Rev. 2020;12:8663.
Li J, Liu R, Rai S, Renhao Z, Xin T, Pan H. Intra-articular vs. intravenous administration: a meta-analysis of tranexamic acid in primary total knee arthroplasty. J Orthop Surg Res. 2020;15(1):581.
Kang B, Li Y, Xu H, Chen-Xin G, Sheng Z, Jing Z, et al. Effect of Multiple Doses of Intravenous Tranexamic Acid on Perioperative Blood Loss in Total Knee Arthroplasty: A Randomized Controlled Study. Orthop Surg. 2020;13(1):126-33.
Wang Z, Shen X. The efficacy of combined intra-articular and intravenous tranexamic acid for blood loss in primary total knee arthroplasty. Medicine. 2017;96(42):e8123.
Cucchi D, Menon A, Zanini B, Riccardo C, Paolo F, Pietro R. Patient-Specific Instrumentation Affects Perioperative Blood Loss in Total Knee Arthroplasty. J Knee Surg. 2018;32(6):483-9.
Xu H, Xie J, Lei Y, Qiang H, Zeyu H, Fuxing P. Closed suction drainage following routine primary total joint arthroplasty is associated with a higher transfusion rate and longer postoperative length of stay: a retrospective cohort study. J Orthop Surg Res. 2019;14(1):163.
Li T, Zhuang Q, Weng X, Lei Z, Yanyan B. Non-continuous versus continuous wound drainage after total knee arthroplasty: a meta-analysis. Int Orthop. 2014;38(2):361-71.
Qi-Dong Z, Wan-Shou G, Qian Z, Zhao-hui L, Li-Ming C, Zi-Rong L, et al. Comparison Between Closed Suction Drainage and Nondrainage in Total Knee Arthroplasty: A Meta-Analysis. J Arthroplasty. 2011;26(8)1265-72.
Migliorini F, Maffulli N, Betsch M, Jörg E, Markus T, Alice B, et al. Closed suction drainages in Lower Limb Joint Arthroplasty: A level I evidence based meta-analysis. Surgeon. 2022;20(3):e51-60.
Märdian S, Matziolis G, Schwabe P. Influence of wound drainage in primary total knee arthroplasty without tourniquet. Int Orthop. 2015;39(3):435-40.
Wang D, Xu J, Zeng W, Kai Z, Tian-Hang X, Zhi C, et al. Closed Suction Drainage Is Not Associated with Faster Recovery after Total Knee Arthroplasty. A Prospective Randomized Controlled Study of 80 Patients. Orthop Surg. 2016;8(2):226-33.
Madan F, Khamis E, Alhassan M, Maryam A, Ahmed S, Mohamed R, et al. Hemoglobin Drop and the Need for Transfusion in Primary Knee Arthroplasty. Cureus. 2022;14(8):e27659.
Watanabe T, Muneta T, Yagishita K, Kenji H, Hideyuki K, Ichiro S, et al. Closed Suction Drainage Is Not Necessary for Total Knee Arthroplasty: A Prospective Study on Simultaneous Bilateral Surgeries of a Mean Follow-Up of 5.5 Years. J Arthroplasty. 2016;31(3):641-5.
Quinn M, Bowe A, Galvin R, Peter Dawson, John O'Byrne, et al. The use of postoperative suction drainage in total knee arthroplasty: a systematic review. Int Orthop. 2015;39(4):653-8.
Yang Z, Chen W, Wu L. Effectiveness and Safety of Tranexamic Acid in Reducing Blood Loss in Total Knee Arthroplasty: A Meta-Analysis. J Bone Joint Surg 2012; 94(13):1153-9.
Dai W, Zhou A, Zhang H. Most Effective Regimen of Tranexamic Acid for Reducing Bleeding and Transfusions in Primary Total Knee Arthroplasty: A Meta-Analysis of Randomized Controlled Trials. J Knee Surg. 2018;31(7):654-63.
Fillingham YA, Ramkumar DB, Jevsevar DS. The Safety of Tranexamic Acid in Total Joint Arthroplasty: A Direct Meta-Analysis. J Arthroplasty. 2018;33(10):3070-82.
Stowers M, Aoina J, Vane A. Tranexamic Acid in Knee Surgery Study-A Multicentered, Randomized, Controlled Trial. J Arthroplasty. 2017;32(11):3379-84.
Jules-Elysee KM, Tseng A, Sculco T, Baaklini LR, McLawhorn AS, Pickard AJ, et al. Comparison of Topical and Intravenous Tranexamic Acid for Total Knee Replacement. J Bone Joint Surg. 2019;101(23):2120-28.
Chen T, Chen Y, Jiao J, Yun-Fei W, Li-Gang Q, Zhao G, et al. Comparison of the effectiveness and safety of topical versus intravenous tranexamic acid in primary total knee arthroplasty: a meta-analysis of randomized controlled trials. J Orthop Surg Res. 2017;12(1):11.
Fillingham Y, Ramkumar D, Jevsevar D, Adolph JY, Peter S, Kyle M, et al. The Efficacy of Tranexamic Acid in Total Knee Arthroplasty: A Network Meta-Analysis. J Arthroplasty. 2018;33(10):3090-98.
Tibesku C, Haas S, Saunders C, Harwood DA. Comparison of clinical outcomes of VISIONAIRE patient‐specific instrumentation with conventional instrumentation in total knee arthroplasty: a systematic literature review and meta‐analysis. Arch Orthop Trauma Surg. 2023;143(7):4379-93.
Rathod P, Deshmukh A, Cushner F. Reducing blood loss in bilateral total knee arthroplasty with patient-specific instrumentation. Orthop Clin North Am. 2015;46(3):343-50.
Gong S, Xu W, Wang R, Zijian W, Bo W, Lizhi H, et al. Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2019;27(4):1083-95.
Voleti P, Hamula M, Baldwin K, Lee GC. Current Data Does Not Support Routine Use of Patient-Specific Instrumentation in Total Knee Arthroplasty. J Arthroplasty. 2014;29(9):1709-12.
Tammachote N, Panichkul P, Kanitnate S. Comparison of Customized Cutting Block and Conventional Cutting Instrument in Total Knee Arthroplasty: A Randomized Controlled Trial. J Arthroplasty 2018;33(3):746-51.
Chareancholvanich K, Narkbunnam R, Pornrattanamaneewong C. A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement. Bone Joint J. 2013;95-B(3):354-9.
Noble J, Moore C, Liu N. The value of patient-matched instrumentation in total knee arthroplasty. J Arthroplasty. 2012;27:153-5.
Spencer BA, Mont MA, McGrath MS, Bradley B, Michael FM. Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment. Int Orthop. 2009;33(6):1571-5.
Thienpont E, Grosu I, Paternostre F, Pierre-Emmanuel S, Jean CY. The use of patient-specific instruments does not reduce blood loss during minimally invasive total knee arthroplasty? Knee Surg Sports Traumatol Arthrosc. 2015;23(7):2055-60.
Vundelinckx B, Bruckers L, De Mulder K, Jo DS, Gert VE. Functional and Radiographic Short-Term Outcome Evaluation of the Visionaire System, a Patient-Matched Instrumentation System for Total Knee Arthroplasty. J Arthroplasty. 2013;28(6):964-70.
Predescu V, Prescura C, Olaru R, Liliana S, Paul B, Bogdan D. Patient specific instrumentation versus conventional knee arthroplasty: comparative study. Int Orthop. 2017;41(7):1361-7.
Pietsch M, Djahani O, Zweiger C, Plattner F, Radl R, Tschauner CH, et al. Custom-fit minimally invasive total knee arthroplasty: effect on blood loss and early clinical outcomes. Knee Surg Sports Traumatol Arthrosc. 2013;21(10):2234-40.
Pereira E, Carvalho M, Oliveira T, Telmo S, Henrique C, Rui V, et al. Benefits of Tranexamic Acid in Total Knee Arthroplasty: A Classification and Regression Tree Analysis in Function of Instrumentation, BMI, and Gender. J Knee Surg. 2023;36(2):173-80.