Functional outcomes, Proximal humerus, PHILOS plating, Radiological outcomesAbstract
Background: Proximal humerus fracture is a common injury near the shoulder joint that poses a significant challenge in management due to its rising incidence and impact on functional recovery. Therefore, the purpose of this study was to evaluate the functional and radiological outcomes of PHILOS plating in the surgical management of proximal humerus fractures.
Methods: This prospective observational study at the Department of Orthopaedic Surgery, BMU, Shahbag, Dhaka and New Life Hospital Limited, Green Road, Dhaka (March 2021–September 2023) included 30 patients with proximal humerus fractures who underwent PHILOS plating. Functional (VAS, Constant Murley Score) and radiological outcomes were assessed at 1, 3, 6 and 12 months. Data were analyzed using SPSS v26 (p<0.05).
Results: In 30 patients treated with PHILOS plating, mean age was 49.1±9.7 years, 53.3% were male and 56.7% had 3-part fractures. Mean union time was 9.57±1.89 weeks. At 6 months, mean flexion was 152.1°±16.7, abduction 156.2°±18.8, internal rotation 67.1°±7.7 and external rotation 73.3°±7.8. VAS improved from 8.33±0.80 to 1.10±0.63 (p<0.001). Mean Constant Murley Score was 84.8±7.0 (excellent 43.3%, good 53.3%, moderate 3.3%). Complications occurred in 13.3% and 86.7% reported satisfactory outcomes.
Conclusions: PHILOS plating provides effective functional recovery, satisfactory pain relief and low complication rates in the management of proximal humerus fractures.
References
Rudran B, Little C, Duff A, Poon H, Tang Q. Proximal humerus fractures: anatomy, diagnosis and management. British J Hosp Med. 2022;2;83(7):1-0.
Fell I, Tashjian RZ, Schroeder NS. Shoulder injuries. In: Aiyer AA, Levine WN, Kaplan JR, Varacallo MA, editors. Orthopaedic Rotations Survival Guide. Philadelphia: Lippincott Williams & Wilkins. 2023: 223–69.
Davey MS, Hurley ET, Anil U, Condren S, Kearney J, O'Tuile C, et al. Management options for proximal humerus fractures–A systematic review & network meta-analysis of randomized control trials. Injury. 2022;53(2):244-9.
Brooker-Thompson C, Mohan H, Chotai N, Baring T. Clinical outcomes of a novel ‘all-suture’fixation for valgus-impacted proximal humeral fractures. Shoulder & Elbow. 2024;16(6):605-10.
Kulkarni R, Sunil Kumar D. A study of functional and radiological outcome of complex fracutre dislocation of proximal humerus treated with proximal humeral internal locking system (Philos) plate. Int J Orthop. 2020;6(4):623-8.
Patel YC, Majumdar S, Shah S, Lathiya H, Bhadani A. Study of outcome of proximal humerus fracture treated with proximal humerus internal locking system (Philos) plating. International J Orthopaed. 2023;9(2):117-26.
Poelmann J, Kloen P. Modified use of the proximal humeral internal locking system (PHILOS) plate for distal femoral nonunions. European Journal of Orthopaedic Sur Traumatol. 2023;33(2):425-33.
Carofino BC, Leopold SS. Classifications in brief: the Neer classification for proximal humerus fractures. 2013.
Schumaier A, Grawe B. Proximal humerus fractures: evaluation and management in the elderly patient. Geriatric Orthopaed Surg Rehab. 2018;20;9:216.
Aliuddin AM, Idrees Z, Zamir M, Najjad MK, Shah SA. Functional outcome of proximal humeral fractures treated with PHILOS plate in adults. J Ayub Medical College Abbottabad. 2016;1;28(2):337-40.
Den Hartog D, Mahabier KC, Van Bergen SH, Verhofstad MH, Van Lieshout EM. Functional and clinical outcomes after plate osteosynthesis versus intramedullary nailing of a humeral shaft fracture: the results of the HUMMER multicenter, prospective cohort study. JBJS. 2023;105(14):1101-11.
Penvose IR, Paxton ES. Proximal Humerus Fracture: Fix, Replace, or Let Heal. Orthopedic Clinics. 2025.
Iglesias-Rodríguez S, Domínguez-Prado DM, García-Reza A, Fernández-Fernández D, Pérez-Alfonso E, García-Piñeiro J, et al. Epidemiology of proximal humerus fractures. J Orthop Surg Res. 2021;22;16(1):402.
Ethiraj P, Venkataraman S, Shanthappa AH, Agarawal S. Does Proximal Humerus Inter Locking System (PHILOS) Plating Provide a Good Functional Outcome in Proximal Humerus Fractures. Cureus. 2022;30;14(6):26474.
Doshi C, Sharma GM, Naik LG, Badgire KS, Qureshi F. Treatment of Proximal Humerus Fractures using PHILOS Plate. J Clin Diagn Res. 2017;11(7):10-3.
Kumar, Velmurugan, Kumar R, Hemapriya. Clinico-radiological outcomes of proximal humerus fractures using locking compression plates among adults in a tertiary care hospital: an observational study. Int J Res Orthop. 2024;10(5):970–4.
Jaura G, Sikdar J, Singh S. Long Term Results of PHILOS Plating and Percutaneous K-Wire Fixation in Proximal Humerus Fractures in The Elderly. Malays Orthop J. 2014;8(1):4-7.
Kushwaha NS, Saini SK, Verma A, Mohan R, Saroj AK, Singh A, et al. Functional Outcome of Osteosynthesis with PHILOS in Elderly Patients: Experience at Tertiary Care Centre. J Orthopaed, Traumatol Rehab. 2023;1;15(1):57-62.
Oldrini LM, Feltri P, Albanese J, Marbach F, Filardo G, Candrian C. PHILOS Synthesis for Proximal Humerus Fractures Has High Complications and Reintervention Rates: A Systematic Review and Meta-Analysis. Life (Basel). 2022;19;12(2):311.