Abstract

Background: Distal radius fractures are one of the most common orthopedic conditions and intra-articular types (AO/ASIF type C) are difficult to treat. While various treatment options exist, external fixation remains valuable, particularly in the developing world. The present study evaluated the efficacy of the Ayjaz Azim foundation (AAF) mini external fixator for the treatment of closed, complete articular distal radius fractures.

Methods: This study evaluated outcomes in 32 patients with closed intra-articular distal radial fractures by purposive sampling. Patients between 18 and 60 years, within two weeks of injury, received standardized surgery. Structured questionnaires were used to collect data, and outcomes at 12 weeks after surgery were assessed using Sarmiento's radiological criteria and the Green and O'Brien functional scoring system. Statistical analysis was performed with SPSS v26, and significance was at p<0.05.

Results: The study population (41.63±12.39 years) had a predominance of males (78.1%), and the most common injury mechanism was motor vehicle accidents (68.75%). Surgery was performed in 90.6% of patients within 24 hours of trauma. Radiologically, 62.5% had excellent results, 31.3% good, and 6.3% fair. The mean loss of volar tilt was 5.03°±3.84°, radial shortening 2.47 mm±2.27 mm, and radial inclination 4.03°±3.27°. Functionally, 62.5% had excellent results, 21.9% good, 12.5% fair, and 3.1% poor. Pin tract infection occurred in 16% of the cases and post-removal stiffness in 62.5% of patients. Radiological and functional results had a good correlation (r=0.876, p<0.001).

Conclusions: AAF mini external fixator is a useful tool for the treatment of AO/ASIF type C distal radius fractures, with 94% patients showing satisfactory results. The technique is reliable for anatomical reconstruction and functional rehabilitation with acceptable complication rates and is a well-suited treatment method worthy of consideration, particularly in regions with limited resources.

Metrics

Metrics Loading ...

References

Nellans KW, Kowalski E, Chung KC. The epidemiology of distal radius fractures. Hand Clin. 2012;28(2):113. DOI: https://doi.org/10.1016/j.hcl.2012.02.001

Mellstrand-Navarro C, Pettersson HJ, Tornqvist H, Ponzer S. The operative treatment of fractures of the distal radius is increasing: results from a nationwide Swedish study. Bone Joint J. 2014;96(7):963-9. DOI: https://doi.org/10.1302/0301-620X.96B7.33149

Koval KJ, Harrast JJ, Anglen JO, Weinstein JN. Fractures of the distal part of the radius: The evolution of practice over time. Where's the evidence? JBJS. 2008;90(9):1855-61. DOI: https://doi.org/10.2106/JBJS.G.01569

Diaz-Garcia RJ, Oda T, Shauver MJ, Chung KC. A systematic review of outcomes and complications of treating unstable distal radius fractures in the elderly. J Hand Surg Am. 2011;36(5):824-35. DOI: https://doi.org/10.1016/j.jhsa.2011.02.005

Xie X, Xie X, Qin H, Shen L, Zhang C. Comparison of internal and external fixation of distal radius fractures: A meta-analysis of randomized controlled trials. Acta Orthopaedica. 2013;84(3):286-91. DOI: https://doi.org/10.3109/17453674.2013.792029

Hanel DP, Lu TS, Weil WM. External fixation of distal radius fractures: A comparison of the Hoffman compact II and Hoffman II frames. Hand. 2006;1(2):71-7.

Dailiana Z, Agorastakis D, Varitimidis S, Bargiotas K, Roidis N, Malizos KN. Use of a mini-external fixator for the treatment of hand fractures. J Hand Surg. 2009;34(4):630-6. DOI: https://doi.org/10.1016/j.jhsa.2008.12.017

Sen D. Principles and Overview of External Fixators in Orthopaedic Traumatology. In Handbook of Orthopaedic Trauma Implantology. Singapore: Springer Nature Singapore. 2023;1-23. DOI: https://doi.org/10.1007/978-981-15-6278-5_16-2

Kreder HJ, Hanel DP, McKee M, Jupiter J, McGillivary G, Swiontkowski MF. X-ray film measurements for healed distal radius fractures. J Hand Surg Am. 1996;21(1):31-9. DOI: https://doi.org/10.1016/S0363-5023(96)80151-1

Slutsky DJ. External fixation of distal radius fractures. J Hand Surg Am. 2007;32(10):1624-37.

Wei DH, Poolman RW, Bhandari M, Wolfe VM, Rosenwasser MP. External fixation versus internal fixation for unstable distal radius fractures: a systematic review and meta-analysis of comparative clinical trials. J Orthop Trauma. 2012;26(7):386-94. DOI: https://doi.org/10.1097/BOT.0b013e318225f63c

Kamano M, Koshimune M, Toyama M, Kazuki K. Palmar plating system for Colles' fractures-application technique and clinical results. J Hand Surg Am. 2005;30(4):750-5. DOI: https://doi.org/10.1016/j.jhsa.2005.02.009

Rundgren J, Bojan A, Mellstrand Navarro C, Enocson A. Epidemiology, classification, treatment and mortality of distal radius fractures in adults: an observational study of 23,394 fractures from the national Swedish fracture register. BMC Musculoskeletal Disord. 2020;21:1-9. DOI: https://doi.org/10.1186/s12891-020-3097-8

Aggarwal D, Sharma S, Gupta M. Porous Mg-Hydroxyapatite Composite Incorporated with Aloe barbadensis Miller for Scaphoid Fracture Fixation: A Natural Drug Loaded Orthopedic Implant. Applied Sci. 2024;14(4):1512. DOI: https://doi.org/10.3390/app14041512

Fanuele J, Koval KJ, Lurie J, Zhou W, Tosteson A, Ring D. Distal radial fracture treatment: what you get may depend on your age and address. JBJS. 2009;91(6):1313-9. DOI: https://doi.org/10.2106/JBJS.H.00448

Castro Obeso JR, Samundeeswari S, Shanmugasundaram S. Intraoperative Imaging Techniques in Orthopaedic Trauma Implantology. InHandbook of Orthopaedic Trauma Implantology. Singapore: Springer Nature Singapore. 2023;1-15. DOI: https://doi.org/10.1007/978-981-15-6278-5_44-2

Schipper IB, Steyerberg EW, Castelein RM, Vugt AB. Reliability of the AO/ASIF classification for pertrochanteric femoral fractures. Acta Orthopaedica Scandinavica. 2001;72(1):36-41. DOI: https://doi.org/10.1080/000164701753606662

Kwok IHY, Leung F, Yuen G. Assessing Results After Distal Radius Fracture Treatment: A Comparison of Objective and Subjective Tools. Geriatric Orthopaedic Surg Rehabilitat. 2011;2(4):155-60. DOI: https://doi.org/10.1177/2151458511422701

Gradl G, Gradl G, Wendt M, Mittlmeier T, Kundt G, Jupiter JB. Non-bridging external fixation employing multiplanar K-wires versus volar locked plating for dorsally displaced fractures of the distal radius. Arch Orthopaed Trauma Surg. 2013;133:595-602. DOI: https://doi.org/10.1007/s00402-013-1698-5

Meena S, Sharma P, Sambharia AK, Dawar A. Fractures of distal radius: an overview. J Family Med Prim Care. 2014;3(4):325-32. DOI: https://doi.org/10.4103/2249-4863.148101

Wei DH, Raizman NM, Bottino CJ, Jobin CM, Strauch RJ, Rosenwasser MP. Unstable distal radial fractures treated with external fixation, a radial column plate, or a volar plate: a prospective randomized trial. JBJS. 2009;91(7):1568-77. DOI: https://doi.org/10.2106/JBJS.H.00722

Kapoor H, Agarwal A, Dhaon BK. Displaced intra-articular fractures of distal radius: a comparative evaluation of results following closed reduction, external fixation and open reduction with internal fixation. Injury. 2000;31(2):75-9. DOI: https://doi.org/10.1016/S0020-1383(99)00207-7

Kopylov P, Johnell O, Redlund-Johnell I, Bengner U. Fractures of the distal end of the radius in young adults: a 30-year follow-up. J Hand Surg Br. 1993;18(1):45-9. DOI: https://doi.org/10.1016/0266-7681(93)90195-L

Mackenney PJ, McQueen MM, Elton R. Prediction of instability in distal radial fractures. J Bone Joint Surg Am. 2006;88(9):1944-51. DOI: https://doi.org/10.2106/00004623-200609000-00006

Krukhaug Y, Ugland S, Lie SA, Hove LM. External fixation of fractures of the distal radius: a randomized comparison of the Hoffman compact II non-bridging fixator and the Dynawrist fixator in 75 patients followed for 1 year. Acta Orthopaedica. 2009;80(1):104-8. DOI: https://doi.org/10.1080/17453670902807433

Chung KC, Shauver MJ, Birkmeyer JD. Trends in the United States in the treatment of distal radial fractures in the elderly. JBJS. 2009;91(8):1868-73. DOI: https://doi.org/10.2106/JBJS.H.01297

Slutsky DJ. External fixation of distal radius fractures. J Hand Surg Am. 2007;32(10):1624-37. DOI: https://doi.org/10.1016/j.jhsa.2007.09.009

Karantana A, Downing ND, Forward DP, Hatton M, Taylor AM, Scammell BE, et al. Surgical treatment of distal radial fractures with a volar locking plate versus conventional percutaneous methods: a randomized controlled trial. JBJS. 2013;95(19):1737-44. DOI: https://doi.org/10.2106/JBJS.L.00232

Downloads

Published

2025-10-27

How to Cite

Dutta, S., Kundu, S., Musa, M., & Rahman, M. S. (2025). Result of management of closed distal radial fracture by Ayjaz Azim foundation mini external fixator. International Journal of Research in Orthopaedics, 11(6), 1333–1339. https://doi.org/10.18203/issn.2455-4510.IntJResOrthop20253408

Issue

Section

Original Research Articles