Functional and radiological outcome of distal femur fracture with intra-articular extension fixed with variable angle-locking compression plate: a prospective study
DOI:
https://doi.org/10.18203/issn.2455-4510.IntJResOrthop20252636Keywords:
Distal femur fracture, Functional outcome, Fracture fixation, Radiological outcome, VA-LCP, Variable angle locking compression plateAbstract
Background: Distal femur fractures, often resulting from high-velocity injuries, pose significant challenges due to their complexity. This study aims to evaluate the efficacy of variable angle-locking compression plate (VA-LCP) in treating these fractures, focusing on both functional and radiological outcomes.
Methods: This prospective observational study included 40 patients aged 20-70 years with distal femur fractures treated at R. L. Jalappa Hospital and Research Centre. Data on demographics, comorbidities, fracture type and outcomes were collected. Patients underwent open reduction and internal fixation with VA-LCP and were followed up at 1 month, 3 months and 6 months postoperatively.
Results: The study revealed significant improvements in functional outcomes as measured by NEER's score, with most patients showing substantial increases by 6 months post-op. The majority of fractures were successfully united within an average of 20 weeks. Complications were minimal and included superficial infections and knee stiffness in a few cases.
Conclusions: VA-LCP provides effective stabilization for distal femur fractures, enabling early mobilization and resulting in positive functional and radiological outcomes. This technique is particularly beneficial for complex intra-articular fractures.
Metrics
References
Ehlinger M, Ducrot G, Adam P, Bonnomet F. Distal femur fractures. Surgical techniques and a review of the literature. Orthopaed Traumatol: Surg Res. 2013;99(3):353-60. DOI: https://doi.org/10.1016/j.otsr.2012.10.014
Batista BB, Salim R, Paccola CA, Kfuri Junior M. Internal fixators: a safe option for managing distal femur fractures. Acta Ortoped Brasileira. 2014;22:159-62. DOI: https://doi.org/10.1590/1413-78522014220300509
Zlowodzki M, Bhandari M, Marek DJ, Cole PA, Kregor PJ. Operative treatment of acute distal femur fractures: systematic review of 2 comparative studies and 45 case series (1989 to 2005). J Orthop Trauma. 2006;20(5):366-71. DOI: https://doi.org/10.1097/00005131-200605000-00013
Salazar BP, Babian AR, DeBaun MR, Githens MF, Chavez GA, Goodnough LH, et al. Distal femur replacement versus surgical fixation for the treatment of geriatric distal femur fractures: a systematic review. J Orthop Trauma. 2021;35(1):2-9. DOI: https://doi.org/10.1097/BOT.0000000000001867
Bhimani R, Bhimani F, Singh RB, Singh P. Enhanced conventional method is as precise as navigation for distal femur resection during total knee replacement: a randomized controlled trial. Research. 2019;8:360. DOI: https://doi.org/10.12688/f1000research.18154.1
Pietu G, Lebaron M, Flecher X, Hulet C, Vandenbussche E. Epidemiology of distal femur fractures in France in 2011–12. Orthopaed Traumatol Surg Res. 2014;100(5):545-8 DOI: https://doi.org/10.1016/j.otsr.2014.06.004
Schandelmaier P, Partenheimer A, Koenemann B, Grün OA, Krettek C. Distal femoral fractures and LISS stabilization. Injury. 2001;32:55-63. DOI: https://doi.org/10.1016/S0020-1383(01)00184-X
Vallier HA, Immler W. Comparison of the 95-degree angled blade plate and the locking condylar plate for the treatment of distal femoral fractures. Journal of orthopaedic trauma. 2012;26(6):327-32. DOI: https://doi.org/10.1097/BOT.0b013e318234d460
Zhu C, Zhang J, Li J, Zhao K, Meng H, Zhu Y, et al. Incidence and predictors of surgical site infection after distal femur fractures treated by open reduction and internal fixation: a prospective single‐ center study. BMC Musculoskeletal Disord. 2021;22:1-10. DOI: https://doi.org/10.1186/s12891-021-04132-9
Deepak Y, Gupta N. Femoral fractures in osteopetrosis. J Trauma Acute Care Surg. 2007;51(5):997. DOI: https://doi.org/10.1097/00005373-200111000-00027
Higgin, Cuthbert A, de Steiger R, Lewis P, Graves SE. Practice variation in total hip arthroplasty versus hemiarthroplasty for treatment of fractured neck of femur in Australia. Bone Joint J. 2019;101(1):92-5. DOI: https://doi.org/10.1302/0301-620X.101B1.BJJ-2018-0666.R1