A study on functional outcome of distal end femur fracture in adults managed with locking compression plate
DOI:
https://doi.org/10.18203/issn.2455-4510.IntJResOrthop20240421Keywords:
Distal end femur, Fracture, Locking compression plate, Union, Weight bearingAbstract
Background: We have evaluated the clinical outcome of surgery using locking compression plate in patients with fracture of distal end of femur in terms of union time, weight bearing and complications.
Methods: The present study was conducted in the department of orthopaedics, Bombay hospital, Indore (M. P.). With a prevalence of 3% of adult distal femoral fracture, the sample obtained was 30 with distal end femur fractures in the study. Protocol of surgery was followed in each patient. Postoperative rehabilitation was also adhered to in all patients.
Results: The mean age of 37.87±11.76 years with a male (25) predominance and more right-side involvement. RTA constituted 90% of the patients. According to AO/ASIF classification, type C1 (23.3%) and type A2 (20%) were the common fracture types seen. The radiological union was achieved in majority by 19-20 weeks. Full weight bearing was started by 15-16 weeks with mean of 18.93±2.02 weeks. In 43.3% patients knee flexion of more than 110 degree was achieved. Infection was seen in 10% patients and limb shortening (<10 mm) was seen in 6.7% patients. According to Neer’s scoring system, 56.7% patients had excellent, 33.3% patients had good, 3.3% patients had fair and 6.7% patients had poor functional outcome.
Conclusions: The treatment of fracture distal end of femur using locking compression plate was found to provide good to excellent functional outcome in majority of the patients, with low prevalence of complications.
References
Coon MS, Best BJ. Distal end femur Fractures. In: StatPearls. Treasure Island (FL): StatPearls Publishing; 2021
Wilson JN. Watson Jone's: Fractures and joint injuries, 6th edi, AEWP publication. 1982;1003-70.
Charnley J. The closed treatment of common fractures. 3rd ed., EWP publication. 2019;197-204.
Krishna C, Shankar RV. Current concept of management of supracondylar femur fracture: retrograde femoral nail or distal femoral locking plate. Int Surg J. 2016;3(3):1356-9.
Wagner M. General principles for the clinical use of the LCP. Injury. 2003;34(2):B31-42.
Pramod G, Vijayakumar AV. Evaluation of the results of locking compression plate in the treatment of fractures lower end of femur. Int J Orthop. 2016;2(4):150-3.
Kiran Kumar GN, Sharma G, Farooque K, Sharma V, Ratan R, Yadav S et al. Locking Compression Plate in Distal Femoral Intra-Articular Fractures: Our Experience. Int Sch Res Notices. 2014;2014:372916.
Mahesh DV, Gunnaiah, Vishwanath. Management of distal end femur fracture by locking compression plate. Int J Health Sci Res. 2014;4(5):235-40.
Kadam AM, Mahadik SK, Rampure S, Jiwami RB. Management of distal femoral fractures with locking compression plate - A prospective study. Asian J Med Sci. 2021;12(1):61-8.
Garg D, Garg RS. Operative management of fracture distal end femur with locking compression plate. Int J Orthop Sci. 2017;3(3):908-11.
Poptani A, Lonikar R. Management of distal end femur fractures with locking compression plate. Available at: https://surgical.medresearch.in/index.php/ijoso/article/view/19/38. Accessed on 10 January, 2024.
Mani K C, Vaishya R, Dirgha Raj R C. Distal femoral fractures fixed by distal femoral locking compression plate: Functional outcomes and complications. Apollo Med. 2018;15:142-6.
Virk JS, Garg SK, Gupta P, Jangira V, Singh J, Rana S. Distal end femur Locking Plate: The Answer to All Distal Femoral Fractures. J Clin Diagn Res. 2016;10(10):RC01-5.