Outcome of dual mobility total hip arthroplasty in patients who are at high risk for dislocation
DOI:
https://doi.org/10.18203/issn.2455-4510.IntJResOrthop20211397Keywords:
THA, DMC, Polyethylene, Intra-prosthetic dislocationAbstract
Background: Dislocation after total hip arthroplasty (THA) remains a major concern, because it is reported to range from 1% to 5%. The concept of dual mobility articulation was developed in 1970 by Bousquet to decrease dislocation risk. Several studies have looked at the outcome of dual mobility articulation in primary THA and in revision THA.
Methods: This is a prospective study of 33 patients undergoing dual mobility THA during 24 months period from October 2017 to September 2019. Patients undergoing total hip replacement (THR) to have dual mobility cup (DMC) were those at high risk of dislocation. Patients were followed up for a mean period of 18 months.
Results: 33 patients (mean age 67 years) underwent DMC THA. 27 patients underwent primary hip replacement. The follow-up of our cases has ranged from 13 months to 3 years with a mean follow-up of 18 months. none of the patients had hip dislocation.
Conclusions: The DMC is an effective solution for the management of high-risk cases undergoing total hip replacement to reduce the incidence of postoperative instability.
References
Berry DJ, Von Knoch M, Schleck CD, Harmsen WS. Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty. J Bone Joint Surg Am. 2005;87:2456-63.
Phillips CB, Barrett JA, Losina E, Mahomed NN, Lingard EA, Guadagnoli E et al. Incidence rates of dislocation, pulmonary embolism, and deep infection during the first six months after elective total hip replacement. J Bone Joint Surg Am. 2003;85:20-6.
Singh JA. Epidemiology of knee and hip arthroplasty: a systematic review. Open Orthop J. 2011;5:80-5.
Sanchez-Sotelo J, Berry DJ. Epidemiology of instability after total hip replacement. Orthop Clin North Am. 2001;32:543-52.
Charnley J. The long-term results of low-friction arthroplasty of the hip performed as a primary intervention. J Bone Joint Surg Br, 1972;54(1):61-76.
Mckee GK, Watson-Farrar J. Replacement of arthritic hips by the Mckee-Farrar prosthesis. J Bone Joint Surg Br 1966;48(2):245-59.
Philippot R, Adam P, Rechhaus M. Prevention of dislocation in total hip revision surgery using a dual mobility design. Orthop Traumatol Surg Res. 2009;95(6):407-13.
Guyen O, Chen QS, Bejui-Hugnes J, Berry DJ, An KN. Unconstrained tripolar hip implants: effect on hip stability. Clin Orthop Relat Res. 2007;455:202-8.
Boyer B, Philippot R, Geringer J, Farizon F. Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hips. Int Orthop. 2012;36(3):511-8.
Hamadouche M, Amoukl H, Bouxin B. Is a cementless dual mobility socket in primary THR a reasonable option? Clin Orthop Relat Res. 2012;470(11):3048-53.
Bouchet R, Mercier N, Saragaglia D. Posterior approach and dislocation rate: a 213 total hip replacements case-control study comparing the dual mobility cup with a conventional 28-mm metal head/polyethylene prosthesis. Orthop Traumatol Surg Res. 2011;97(1):2-7.
Combes A, Migaud H, Girard J, Duhamel A, Fessy MH. Low rate of dislocation of dual mobility cups in primary total hip arthroplasty. Clin Orthop Relat Res. 2013;471(12):3891-900.
Philippot R, Farizon F, Camilleri JP. Survival of cementless dual mobility socket with a mean 17 years follow-up. Rev Chir Orthop Reparatrice Appar Mot. 2008;94(8):e23-7.
Tarasevicius S, Robertsson O, Dobaz-inskas P, Wingstrand H. A comparison of outcomes and dislocation rates using dual articulation cups and THA for intracapsular femoral neck fractures. Hip Int. 2013;23(1):22-6.
Leiber-Wackenbeim F, Brunsch-weikr B, Ehlinger M,Gabrion A, Mertl P. Treatment of recurrent THR dislocation using of a cementless dual mobility cup: a 59 cases series with a mean 8 years follow-up. Orthop Traumatol Surg Res. 2011;97(1):8-13.
Massin P, Besnier L. Acetabular revision using a press fit dual mobility cup. Orthop Traumatal Surg Res. 2010;96(1):9-13.
Hamadouche M, Biau DJ, Huten D, Musset T, Gauher F. The use of a cemented dual mobility socket to treat recurrent dislocation. Clin Orthop Relat Res. 2010;468(12):3248-54.
Wegrzyn J, Pibarot V, Jacquel A, Carret JP, Bejui-Hugues J, Guyen O. Acetabular reconstruction using a Kerboull cross-plate, structural allograft and cemented dual-mobility cup in revision THA at a minimum 5-year follow-up. J Arthroplasty. 2014;29(2):432-7.
Langlais FL, Ropars M, Gaucher F, Musset T, Chaix O. Dual mobility cemented cups have low dislocations rates in THA revisions. Clin Orthop Relat Res. 2008;466(2):389-95.
Prudhon JL, Steffann F, Ferreira A, Verdier R, Aslanian T, Caton J. Cementless dual-mobility cup in total hip arthroplasty revision. Int Orthop. 2014;38(12):2463-8.
Guyen O, Chen QS, Bejui-Hugnes J, Berry DJ, An KN. Unconstrained tripolar hip implants: effect on hip stability. Clin Orthop Relat Res. 2007;455:202-8.
Boyer B, Philippot R, Geringer J, Farizon F. Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hips. Int Orthop. 2012;36(3):511-8.
Bouchet R, Mercier N, Saragaglia D. Posterior approach and dislocation rate: a 213 total hip replacements case-control study comparing the dual mobility cup with a conventional 28-mm metal head/polyethylene prosthesis. Orthop Traumatol Surg Res. 2011;97(1):2-7.
Farizon F, de Lavison R, Azoulai JJ, Bousquet G. Results with a cementless alumina-coated cup with dual mobility. A twelve-year follow-up studies. Int Orthop. 1998;22:219-24.
Philippot R, Adam P, Rechhaus M. Prevention of dislocation in total hip revision surgery using a dual mobility design. Orthop Traumatol Surg Res. 2009;95(6):407-13.
Prudhon JL. Dual-mobility cup and cemented femoral component: 6-year follow-up results. Hip Int. 2011;21(6):713-7.
Massin P, Besnier L. Acetabular revision using a press fit dual mobility cup. Orthop Traumatal Surg Res. 2010;96(1):9-13.
Hamadouche M, Biau DJ, Huten D, Musset T, Gauher F. The use of a cemented dual mobility socket to treat recurrent dislocation. Clin Orthop Relat Res. 2010;468(12):3248-54.
Prudhon JL, Steffann F, Ferreira A, Verdier R, Aslanian T, Caton J. Cementless dual-mobility cup in total hip arthroplasty revision. Int Orthop. 2014;38(12):2463-8.
Guyen O, Pibarot V, Vaz G, Chevillotte C, Béjui-Hugues J. Use of a dual mobility socket to manage total hip arthroplasty instability. Clin Orthop Relat Res. 2009;467:465-72.
Combes A, Migaud H, Girard J, Duhamel A, Fessy MH. Low rate of dislocation of dual mobility cups in primary total hip arthroplasty. Clin Orthop Relat Res. 2013;471(12):3891-900.
Boyer B, Philippot R, Geringer J, Farizon F. Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hips. Int Orthop. 2012;36(3):511-8.
Mohammed R, Cnudde P. Severe metallosis owing to intraprosthetic dislocation in a failed dual-mobility cup primary total hip arthroplasty. J Arthroplasty. 2012;27(3):493.e1-3.
Berry DJ. Epidemiology-Hip and knee. Orthopedic clinics of North America. 1999;30(2):183-90.