Background: The concept of hip Arthroplasty started as a very simple rudimentary idea of excising the hip joint (excision Arthroplasty), through to fusion of the hip, to actual replacement of the joint surfaces with various artificial substances ranging from glass, plastic, pig's bladder, ivory, ceramic polyethylene (PE) and more recently to actual metal-on metal hip replacement. Hip replacement is usually considered only after other therapies, such as physical therapy and pain medications, have failed. To determine the combined femoral and acetabular anteversion in patients undergoing total hip arthroplasty using CT scan.

Methods: Patients admitted in hospital who underwent total hip arthroplasty from July 2013 to July 2015 were included in the study.

Results: The study comprised of 40 patients, there were 15 (37.5%) females and 25 (62.5%) males. There were 7(17.5%) patients with less than 30º femoral component anteversion, 26 (65%) patients were in the range of 30º - 50º anteversion and 7 (17.5%) patients were in the range of more than 50º anteversion. There were 10 (25%) patients with less than 40 º combined anteversion, 23 (57.5%) patients were in the range of 40 º - 70 º anteversion and 7 (17.5 %) patients were in the range of more than 70 º anteversion.

Conclusions: The functional outcome of the patients was better when the combined anteversion was between 4-7ff as compared to the functional outcome when the combined anteversion was either less than 40 " or more than 70'.  However, we required larger group of study to validate the findings.

Author Biographies

Harish Murthy, Associate Professor, Department of Orthopaedics, Raichur Institute of Medical Sciences, Raichur

Associate Professor

Department of Orthopaedics

T. V. S. Reddy, Surxa Hospital, Kurnool, India

Surxa Hospital, Kurnool

References

Knight SR, Aujla R, Biswas SP. Total Hip Arthroplasty - over 100 years of operative history. Orthopedic Reviews. 2011;3:el6.

Abdulkarim A, Prasad E, Nicola M, Tom F, John MO. Cemented versus uncemented fixation in total hip replacement: a systematic review and meta-analysis of randomized controlled trials. Orthopedic Reviews. 2013;5:e8.

BizotP, Nizard R, Hamadouche M. Prevention of wear and osteolysis: alumina-on-alumina bearing. Clin Orthop Relat Res. 2001;393:85-93.

Reikeris O, Gunderson RB. Components anteversion in primary cementless THA using snaight stem and hemispherical cup: A prospective study in 9l hips using CT-scan measurements. Orthop Traumatol Surg Res. 2006;97(6):615-21.

Wines AP, McNicol D. Computed tomography measurement of the accuracy of component version in total hip arthroplasty. J Arthroplasty. 2006;2r(5):696-701.

Maheshwari AV, Zlowodzki MP, Siram G. Femoral neck anteversion, acetabular anteversion and combined anteversion in the normal Indian adurt popuration: A computed tomographic study. Indian Journal of orthopaedics. 2010;44(3),277182.

Fujishiro T, Hayashi S, Kanzaki N, Kanno T. Computed tomographic measurement of acetabular and femoral component version in total hip arthroplasty. Int Orthop. 2014;38(5):941-6.

Lewinnek GE, Lewis JL, Tan R, Compere CL, Zimmerman JR. Disrocations after total hip-replacement arthroplasties. J Bone Joint surg Am. 1978:60:21710.